Model number:E00145
Product Name:Circuit Breakers
Area Made:South Africa
Explanation:BA4000-H drow out type Intelligent controller:Standard type(M).Communication(H) Standrads:CNS14816-2 (IEC60947-2) Type:drawer type.manual type and electric type Voltage Ue:690V Rated isolated voltage Ui:1000V Current In:4000A Rated adjust current:0.4~1.0In Control voltage:AC110V.AC220V.AC380V DC110V.DC220V Pole: 3P 4P Contacts:4C Breaking capacity: Icu: 380V / 130kA 440V / 100kA Ics = 100% Icu Icw : 380V/ 100kA
Model number:E00144
Product Name:Circuit Breakers
Area Made:South Africa
Explanation:BL400-CN Thermal magnetic Standards:CNS14816-2 (IEC60947-2) Voltage:110~440V Current:250.300.350.400A Pole: 3P 4P Rated current sensitivity:30/100/500mA(high speed). 100/300/500mA(delay type)stated on order Operating time:0.1s(high speed). 0.45/1.0/2.0(delay time) Breaking Capacity: Icu: 220V/ 35kA (sym) 380V/ 25kA (sym) 440V/ 22kA (sym) Ics = 50% Icu Accessories: AL.AUX.SHT.UVT.EH400N(IP30.IP52).TC400N.
Model number:E00143
Product Name:Circuit Breakers
Area Made:South Africa
Explanation:BL100-SN Hydraulic magnetic Standards:CNS5422 (IEC60947-2) Voltage:110~440V Rated Current:15.20.30.40.50.60.75.100A Pole: 3P 4P Rated current sensitivity:30mA(15.50.100mA) Operating time:0.1s(high speed) Breaking capacity: Icu: 220V/ 25kA (sym) 380V/ 15kA (sym) 440V/ 10kA (sym) Ics = 50% Icu Accessories: AL.AUX.SHT.UVT(4P).EH125N(IP30.IP52).TC125N.TC125NS
Model number:E00060
Product Name:Circuit Breakers
Area Made:South Africa
Explanation:BPL Standards:CNS14816-2 (IEC60947-2) Voltage Ui:110~380V Current:15.20.30.40.50.60.75.100A Pole: 1P 2P 3P Breaking capacity: Icu: 1P 110V/ 5kA (sym) 2P 220V/ 5kA (sym) 3P 220V/ 5kA (sym) Ics = 50% Icu
Model number:E00057
Product Name:Circuit Breakers
Area Made:South Africa
Explanation:NF1200-E Electrical Type Standards:CNS14816-2 (IEC60947-2) Voltage Ui:690V Current:600~2000A adjustable Pole: 3P Breaking Capacity: Icu: 220V/ 125kA (sym) 380V/ 85kA (sym) 440V/ 85kA (sym) Ics = 50% Icu
Model number:E00056
Product Name:Circuit Breakers
Area Made:South Africa
Explanation:BM50-HN Hydraulic magnetic Standards:CNS14816-2 (IEC60947-2) Voltage Ui:690V Current:10.15.20.30.40.50A Pole: 2P 3P 4P Breaking Capacity: Icu: 220V/ 25kA (sym) 380V/ 15kA (sym) 440V/ 10kA (sym) Ics = 50% Icu Accessories: AL.AUX.SHT.UVT.EH100N(IP30.IP52).TC100N.TC100NS